Home » PRODUCTS » Specialized Drive » Air Compressor Industry

HLP-SK190 Air Compressor Drive

HLP-SK190 serial is a special compressor product. It is applied to asynchronous and synchronous motor field in compressor market; 

Applications:

asynchronous and synchronous motor

Characteristic

High Reliability

High Environmental Adaptability


 
  • Long life design
  • Fan speed controllable
  • Strict design and test production system
  • Apply to control induction motors and permanent magnet synchronous motors
  • Automatic load compensation feature to ensure the stability of air pressure when the load fluctuation
 
  • Independent wind way design
  • PCBA full coating coverage
  • Wide tooth pitch radiator
  • Easy cleaning and replacement fan
  • Provide IP5X options
  • Wide voltage range
  • High adaptability EMC characteristics
  • Intelligent heating management system

 

 

 

  

 

 

Excellent User Friendliness  
 
  • Easy operation
  • IO board customization
  • Smaller size
  • Multiple installation mode
  •  Simple operation menu, powerful monitoring capability
 

Excellent Control Performance

   
 
  • Unique synchronous motor control algorithm, precise static Automatic Motor Adaption(AMA) function, to ensure the high performance of permanent magnet synchronous motor control
  • Completed compressor control craft, not only to fully meet the overall compressor process control requirements, but also greatly simplifies system design

 

   
Tech. Specifications
Item  Specification
Power supply Supply voltage

Three phase 380~480V -20%~+10%;

Frequency  48-62Hz;
Max. imbalance   3% ;
Motor output Output voltage   Three phase  0-100% of supply voltage
Output frequency   V/F : 0-400Hz , VVC+: 0-200Hz;

IO

board

control

terminals

 

   
 Input

  6 digital inputs (1 supports pulse input, pulse range: 1Hz~100kHz);

  2 analog input, both can receive voltage or current signals.
 Output

  2 digital output;

  2 relay output;

  2 analog input (1 can be selected as current output or voltage output via jumper switch).
 Power supply

  1 +10V, max current output 10mA;

  1 24V, max current output 200mA;
 Communication  RS+, RS-, max baud rate 115200bit/s;
 Display   8 segments, 5 numeric displays   Display frequency, warnings, status and so on;
 Indicator  Light FWD, REV, HZ, A, RPM display various status of the drive; 
 Data read-outs   Frequency setting, output frequency, feedback value, output current, DC link voltage, output voltage, output power, input terminals state, output terminals state,  analogue input , analogue output, 1-10 fault records and accumulated working time etc.;
 Environment     Enclosure  IP20;
 Ambient temperature  -10℃~50℃, derating use when over 40℃;
 Humidity  5%-85% (95% without condensation);
 Vibration test  ≤75kW: 1.14g;
 ≥90kW: 0.7g;
 Max. altitude above sea level  1000m, derating use when more than 1000 meters;
 Motor cable length  Shield cable: 50 meters; Unshield cable: 100 meters;
Others  DC choke  ≥37kW Built-in
 Braking unit

 ≤22kW Built-in

Product Functions
Main control functions Control mode V/F, VVC+;
Start torque 0.5Hz 150%;
Overload capacity 150% 60s, 200% 1s;
PWM switch frequency 2k~16kHz ;
Speed setting resolution

Digital: 0.001Hz;

Analogy: 0.5‰ of the max. operating frequency ;

Speed open-loop control accuracy

30~4000 rpm: tolerance±8 rpm;
Control command source LCP, digital terminal, local bus;
Frequency setting source LCP, analog, pulse, local bus;
Ramp control Selectable 4-speed steps ramp up and down times 0.05-3600.00s;
Basic Functions Speed Open-loop Control; Process Closed-loop Control; Torque Open-loop Control; AMA Function; Motor Magnetisation; Slip Compensation; Torque compensation; Automatic Voltage Regulation;  V/F Control, DC Brake; AC brake; Speed Limit; Current Limit; Flying Start; Reset Function; Counter; Timer;
Application Functions Compressor control craft mode; Jogging;  Multi-speed  Control via Digital input; SLC(including Order Control and Parallel Control); Mechanical Braking; UP/DOWN ; Catch up /Slow down; Relative Scaling Reference etc.

Protection

Functions
Missing Motor Phase Protection; Low-voltage Protection; Over-voltage Protection; Over-current Protection; Output Phase Loss Protection; Output Short Circuit Protection; Output Grounding Fault Protection; Motor Thermal Protection; Live Zero Timeout Function; AMA Fails; CPU Fault; EEPROM Faults; Button freeze; Duplicate Fails; LCP Invalid; LCP Incompatible; Parameter Read-only; Reference Out of Range; Invalid While Running etc.
Particular Specifications
Model   Input voltage

Input current

(A)

Output current 

(A) 

Rated power

 (kw)

Suitable motor

 (kw)

 Net weight

(kg)

HLP-SK19004D043

3×380-440V50/60Hz

14.4 9.9 4.0  4.0 

3×440-480V50/60Hz

12.4  8.9 
HLP-SK19005D543   3×380-440V50/60Hz
19.2  13.3  5.5   5.5   2  
3×440-480V50/60Hz  16.6  12 
HLP-SK19007D543    3×380-440V50/60Hz 24.8 17.7  7.5   7.5   2.5  
3×440-480V50/60Hz
21.4  16 
HLP-SK190001143   3×380-440V50/60Hz
35.9  25  11   11   5.8  
3×440-480V50/60Hz  31.4  22.7 
HLP-SK190001543   3×380-440V50/60Hz
43.4 32  15   15  5.8  
3×440-480V50/60Hz  38.8  29.1 

HLP-SK19018D543

3×380-440V50/60Hz 51.5  38  18.5   18.5   8  
3×440-480V50/60Hz  46.1 34.5 
HLP-SK190002243    3×380-440V50/60Hz 61.0 45  22   22   8  
3×440-480V50/60Hz  54.5  40.9 
HLP-SK190003043    3×380-440V50/60Hz 73  61  30   30   19  
3×440-480V50/60Hz  64 52 
HLP-SK190003743   3×380-440V50/60Hz 72  75  37   37   22  
3×440-480V50/60Hz  65  68 
HLP-SK190004543   3×380-440V50/60Hz  86  91  45   45   26  
3×440-480V50/60Hz  80  82 
HLP-SK190005543   3×380-440V50/60Hz  110  112  55   55   26  
3×440-480V50/60Hz  108  110 
HLP-SK190007543   3×380-440V50/60Hz  148  150  75   75   37  
3×440-480V50/60Hz  135  140 
HLP-SK190009043   3×380-440V50/60Hz  175  180  90   90   60  
3×440-480V50/60Hz  154  160 
HLP-SK190011043   3×380-440V50/60Hz  206  215  110   110   60  
3×440-480V50/60Hz
183 190 
HLP-SK190013243   3×380-440V50/60Hz
251  260  132   132   60  
3×440-480V50/60Hz  231  240 
HLP-SK190016043
3×380-440V50/60Hz  304  315  160   160   99  
3×440-480V50/60Hz
291  302 
HLP-SK190018543   3×380-440V50/60Hz  350  365  185   185   99  
3×440-480V50/60Hz
320 335 
HLP-SK190020043   3×380-440V50/60Hz  381 395  200   200   99  
3×440-480V50/60Hz  348  361 
HLP-SK190022043   3×380-440V50/60Hz  420  435  220   220   99  
3×440-480V50/60Hz
383  398 
HLP-SK190025043   3×380-440V50/60Hz  472  480  250   250   250  
3×440-480V50/60Hz
436  443 
HLP-SK190028043   3×380-440V50/60Hz  525  540  280   280   250  
3×440-480V50/60Hz
436  490
HLP-SK190031543   3×380-440V50/60Hz  590 605 315  315   250  
3×440-480V50/60Hz  531 540 
HLP-SK190035543
3×380-440V50/60Hz  647  605  355   355   250  
3×440-480V50/60Hz  580 590
HLP-SK190041543   3×380-440V50/60Hz
718 745  415   415   250  
3×440-480V50/60Hz  653  678 
Installation Dimensions

Installation ModelDimensions(mm)
W H D W1 H1 W2 d

Wall 

Mounting

 

HLP-SK19004D043 145 250 167 124 230 - 4.5
HLP-SK19005D543
HLP-SK19007D543  155 263 177 133 243 4.5
HLP-SK190001143  192 365 189 150 340  -  6.5
HLP-SK190001543 
HLP-SK19018D543  216 420 194 150  395  -   6.5 
HLP-SK190002243 
HLP-SK190003043  292  517  229  240  492 -  
HLP-SK190003743
HLP-SK190004543
292   562  249  240  537  -   9  
HLP-SK190005543 
HLP-SK190007543
292  665  277  240  640
HLP-SK190009043
350    799    375    220    765    280    10.5   
HLP-SK190011043 
HLP-SK190013243 
HLP-SK190016043
486     900     390     345     863     410     10.5    
HLP-SK190018543
HLP-SK190020043
HLP-SK190022043
HLP-SK190025043  600      1628      509      440      1578      520      15     
HLP-SK190028043 
HLP-SK190031543
HLP-SK190035543 
HLP-SK190041543

Cabinet

HLP-SK190025043  600      1568      509      424      304      -      15     
HLP-SK190028043
HLP-SK190031543
HLP-SK190035543
HLP-SK190041543 
Welcome to Holip website
If you need any help, please fill in the blanks below,
we will contact you as soon as we receive your requirements.
在线表单
Your name :
Your E-mail :
The product model :
Problem Description :