Home » PRODUCTS » Standard Drive

A150 Series Standard Drive

A150 series drive is a new generation of standard vector inverter developed by Holip, using future-oriented modular design concept. The whole machine is divided into control unit(CU),power unit(PU),optional card,LCP and covers.Modules can be configured in the best way according to the application requirements, providing high flexibility for the applications.

Applications:

plastics, textiles, machine tools, food packaging, chemicals, printing, building materials, stone, wire drawing, glass, ball mills, environmental, overloading fan machinery, etc.

Characteristic

Flexible 

Reliable

 

 
  • Modular design
  • PU can work independently
  • Multi-Motor  Control
  • Compact
 
  • 50°C Without derating
  • Independent duct design
  • Enhanced coated circuit board
  • Built-in RFI filter
  • Wide voltage range design
  • Kinetic Energy Back-up
Easy to Use   
 
  • Screwless Wiring of Control Terminal
  • U-type screw hole design
  • Easy cleaning and replacement fan design
  • Partial fanless design
 

Communicative

   
 
  • Supports Modbus, Profibus-DP, Profinet and IoT
   
Tech. Specifications
Item  Specification
Power supply Supply voltage

Single/three phase 200~240V -20%~+10%;

  Three phase 380~480V -20%~+10%;

Frequency  48-62Hz;
Max. imbalance   3% ;
Motor output Output voltage   Three phase  0-100% of supply voltage
Output frequency   0-400Hz 

IO

board

control

terminals

 

   
 Input

  5 digital inputs (1 supports pulse input, pulse range: 1Hz~100kHz);

  2 analog input, both can receive voltage or current signals.
 Output

  1 digital output (supports pulse output, pulse range: 1Hz~100kHz);

  1 relay output;

  1 analog input (supports current output or voltage output via parameter).
 Power supply

  1 +10V, max current output 10mA;

 Communication  RS+, RS-, max baud rate 115200bit/s;
 Display   8 segments, 5 numeric displays   Display frequency, warnings, status and so on;
 Indicator  Light FWD, REV, HZ, A, RPM display various status of the drive; 
 Data read-outs   Frequency setting, output frequency, feedback value, output current, DC link voltage, output voltage, output power, input terminals state, output terminals state,  analogue input , analogue output, 1-10 fault records and accumulated working time etc.;
 Environment     Enclosure  IP20;
 Ambient temperature  -10℃~60℃, derating use when over 50℃;
 Humidity  5%-85% (95% without condensation);
 Vibration test  ≤75kW: 1.14g;
 ≥90kW: 0.7g;
 Max. altitude above sea level  1000m, derating use when more than 1000 meters;
 Motor cable length  Shield cable: 50 meters; Unshield cable: 100 meters;
Others  DC choke  none
 Braking unit

 Built-in

Product Functions
Main control functions Control mode V/F, VVC+;
Start torque 0.5Hz 150%;
Overload capacity 150% 60s, 200% 1s;
PWM switch frequency 2~16kHz ;
Speed setting resolution

Digital: 0.001Hz;

Analogy: 0.5‰ of the max. operating frequency ;

Speed open-loop control accuracy

30~4000 rpm: tolerance±8 rpm;
Control command source LCP, digital terminal, local bus;
Frequency setting source LCP, analog, pulse, local bus;
Ramp control Selectable 4-speed steps ramp up and down times 0.05-3600.00s;
Basic Functions Speed Open-loop Control; Process Closed-loop Control; Torque Open-loop Control; AMA Function; Motor Magnetisation; Slip Compensation; Torque compensation; Automatic Voltage Regulation;  V/F Control, DC Brake; AC brake; Speed Limit; Current Limit; Flying Start; Reset Function; Counter; Timer;Jogging; Multi-speed Control via Digital input; Mechanical Braking; UP/DOWN;  

Protection

Functions
Missing Motor Phase Protection; Low-voltage Protection; Over-voltage Protection; Over-current Protection; Output Phase Loss Protection; Output Short Circuit Protection; Output Grounding Fault Protection; Motor Thermal Protection; Live Zero Timeout Function; AMA Fails; CPU Fault; EEPROM Faults; Button freeze; Duplicate Fails; LCP Invalid; LCP Incompatible; Parameter Read-only; Reference Out of Range; Invalid While Running etc.
Particular Specifications
Model   Input voltage

Input current

(A)

Output current

(A)

Rated power

(kW)

Power

Dissipation

 (W)

Air flow rate

(m3/h)

Net weight

(kg)

A150-0D3723 

1×200-240V

 6.3 2.5  0.37  18.2 0 0.8
200-240V 3.6 2.5  17.3

A150-0D7523 

1×200-240V 11.3 4.5 0.75 28.3 17.2 0.9
200-240V
6.5  4.5 26.8

A150-01D523

1×200-240V  18.5  7.5 1.5   55.1 17.2   0.9  
200-240V
10.9 6.8  44.4

A150-02D223

1×200-240V
23.9 9.6  2.2   59.9   45.5   1.5
200-240V
13.9 9.6 

A150-0D7543

3×380-440V   3.1 2.1  0.75   35.6 0   0.8 
3×440-480V
2.8 1.9 

A150-01D543

3×380-440V   5.5  3.8  1.5   43.3   17.2   0.9  
3×440-480V  5.0  3.4 

A150-02D243

3×380-440V  7.3 5.1 2.2  59.6 17.2  0.9  
3×440-480V 
6.6  4.6

A150-04D043

3×380-440V  12.9  9.0  4.0   101.6   45.5  1.5  
3×440-480V 
11.6  8.1

A150-05D543

3×380-440V  18.9  13.0  5.5   128.5   90.0   2.0  
3×440-480V 
17.1 11.7

A150-07D543

3×380-440V   24.5  17.0 7.5   188.7   90.0    2.0 
3×440-480V   22.1  15.3 
Installation Dimensions

 

FrameVoltage & Power Dimensions(mm)
  3x200-240V 3x380-480V W H D W1 H1 d
NA0-A  0.37 kW  0.75 kW 72 170 150 60 150 4.5
NA-B  0.75-1.5 kW 1.5-2.2 kW 72 185 150 55 175 4.5
NA1  2.2 kW  4.0 kW 88 215 155 70 205 4.5
NA2 - 5.5-7.5 kW 100 250 160 80 240 4.5
Welcome to Holip website
If you need any help, please fill in the blanks below,
we will contact you as soon as we receive your requirements.
在线表单
Your name :
Your E-mail :
The product model :
Problem Description :